Step | | Procedure & Parts & Tools |
1 |
|
PULL THE TANK COVER HANDLE OUT AT FRONT OF COVER AND RAISE THE COVER UP TO OPEN.
|
2 |
|
REMOVE THE 6 SCREWS FROM THE VAC MOTOR PLATE.
Torx T30 |
|
|
3 |
|
REMOVE THE VAC MOTOR COVER FROM MACHINE.
|
4 |
|
SLIDE THE VAC MOTOR COLLAR OUT TO REMOVE THE VAC MOTOR FROM THE MACHINE.
|
5 |
|
LOCATE THE WHITE CONNECTOR PLUG. INSERT PROBES INTO THE CONNECTOR PLUG. RED PROBE TO RED WIRE AND BLACK PROBE TO BLACK WIRE. TURN VOLT METER TO VOLTAGE. VOLT METER SHOULD READ 24 VOLTS. IF VAC MOTOR IS OKAY, REVERSE STEPS 1 THRU 4 TO REASSEMBLE THE MACHINE.
Volt meter (True RMS capable) |
|
|